Models | Installation | Sensor | Flow Chart on Model R90 | Flow Chart on Model Mini180 | Data |
S MODEL |
R Single
R Double R Triple R Quadruple R Mini R componible R Modular |
HALL
REED |
Flow Chart | Flow Chart |
Performance: 0,5-3,6 L/min
Nominal pulse/liter:2337-3162 Tolerance: ± 5% Magnet No: 2 No ByPass |
M MODEL |
R Single
R Double R Triple R Quadruple R Mini R componible R Modular |
HALL
REED |
Flow Chart | Flow Chart |
Performance: 1-7 L/min
Nominal pulse/liter:672-1008 Tolerance: ± 5% Magnet No: 1 No ByPass |
L MODEL |
R Single
R Double R Triple R Quadruple R Mini R componible R Modular |
HALL
REED |
Flow Chart | Flow Chart |
Performance: 3-15 L/min
Nominal pulse/liter:412-618 Tolerance: ± 5% Magnet No: 2 With ByPass |
XL MODEL |
R Single
R Double R Triple R Quadruple R Mini R componible R Modular |
HALL
REED |
Flow Chart | Flow Chart |
Performance: 5-30 L/min
Nominal pulse/liter:248-372 Tolerance: ± 5% Magnet No: 2 With ByPass |
*The values specified must be considered as approximate values.
The number of pulses per litre may differ depending on medium and installation. We recommend to calibrate the number of pulses per litre in line with the complete installation. |
|||||
**Measured values according to RPE test protocol with 5 bar pressure,
output at 1L/min for the S model, 2L/min for the M model, 5 L/min for the L model, 10 L/min for the XL model. |
Hall sensor | Reed sensor | ||
Voltage: 5-28V DC | Voltage: 5-28V DC | ||
Current: 10 mA maximum | Current: 500 mA maximum | ||
Connector: Tripolar Male back connector | Connector: Tripolar Male back connector | ||
Cable: Tripolar Female -Red connector | Cable: Bipolar Female -white connector | ||
Brown cable: positive pole | Brown cable: output signal | ||
Green cable: ngative pole | white cable: output signal | ||
white cable: output signal | |||
HALL scheme | REED scheme | ||
HALL draw | REED draw |